How can I filter fluctuating weighing data?

Filter settings

Through optional filters, the scale to be configured for use in harsh / unstable environments as well as for weighing moving items such as liquids and live animals.

The possible filter levels range from 1 to 7. Lower filter levels mean that fluctuations through movements and vibrations are more visible in the displayed weight. The default value is level 2 (factory setting).

Additional filter for weighing live animals or people that, when moving on the weighing plate, cause vibrations in the weight indicator by exerting a variable force on the load cells.

In the ON setting, the indicator does not show in-between values when the scale is loaded or unloaded. The result is that the indicator maintains the last stable value until a new stable or zero weight is reached.

A/D converter sampling speed. 12 sps / 50 sps (samples per second). A higher sampling rate per second results in the weight being calculated faster, but also shows short spikes due to blows or draught.

Output rate for sending data from the Xtrem scale to the K3X terminal in milliseconds. Enter the value in milliseconds. The default value is 50 ms (factory setting).


Level

Motion Filter

Speed

0